==SCMC== | ==SCMC== | ||
− | * change cutoff freq to ~15Khz for temp circuit (U22) R102=1k, C73=0.01u | + | * pg 7/18 : change cutoff freq to ~15Khz for temp circuit (U22) R102=1k, C73=0.01u |
* pg 7/18 : remove R232 - 10k for batt_temp_mon pullup | * pg 7/18 : remove R232 - 10k for batt_temp_mon pullup | ||
Line 40: | Line 40: | ||
* pg 8/18 : populate so measurement of supply voltage is default (R222, R233 installed). its easier to remove components than to add them. | * pg 8/18 : populate so measurement of supply voltage is default (R222, R233 installed). its easier to remove components than to add them. | ||
− | |||
* pg 3/18 : replace 1.25mm header for EC30 enc/hall w/ 12x0.8mm header | * pg 3/18 : replace 1.25mm header for EC30 enc/hall w/ 12x0.8mm header | ||
** [[http://mediawiki.dideas.com/index.php?title=Upd_2x0_218_controller#pinout 12x8 pinout]] | ** [[http://mediawiki.dideas.com/index.php?title=Upd_2x0_218_controller#pinout 12x8 pinout]] | ||
** [http://dhcp-17-197.media.mit.edu/ankle/for_mpd/prelim-EMILE3_070709.pdf interface cable] | ** [http://dhcp-17-197.media.mit.edu/ankle/for_mpd/prelim-EMILE3_070709.pdf interface cable] | ||
− | |||
− | * | + | * pg 6/18 : replace HALL_C input with SSI_CLK 5V output |
− | * need to | + | * pg 11/18 : (CB) need to determine the accuracy of the RTC. Seems to be drifting. |
− | |||
− | |||
− | * locate IMU header for | + | * pg 18/18 : Remove LSSGA before TP56 |
− | ** KS - lower position. CB in V2 appears to be much more space in the shell | + | |
+ | * Connect TP56 to LSSGA connector. needs to protect dsPIC, but no other circuity. | ||
+ | ** adjust C95 for 15khz cutoff freq | ||
+ | * pg 14/18 : Connect TP252 to LSSGA connector. Needs to protect dsPIC, but no other circuity. | ||
+ | |||
+ | |||
+ | * 3/18 : LSSGA connector signals: | ||
+ | ** AGND | ||
+ | ** A3V ref | ||
+ | ** A 3V supply | ||
+ | ** TP56 analog in | ||
+ | ** TP252 analog in | ||
+ | |||
+ | |||
+ | |||
+ | * locate IMU header for easier access. possibly rot180 - or move 2mm away from edge. | ||
+ | ** KS - lower position for V2. | ||
+ | ** CB - in V2 appears to be much more space in the shell, no other changes may be needed. | ||
==IMU== | ==IMU== | ||
* probably want to upgrade dual axis IMU | * probably want to upgrade dual axis IMU | ||
* battery measurement circuit needs to be re-done. | * battery measurement circuit needs to be re-done. |
Revision as of 21:45, 30 September 2009
- PF Top Nav; PCB; Hardware; Assembly PFCmdMenu iochan
- PCA : SC/MC 218 FET 217 IMU219 Swiffy Rev200_mods
- PFCMD : SC; MC; PFCMD_PY; Pf_calb_table_py; Virtual spring test; PF1_Code_History; PF EEPROM
- SERIES: S01 S02 S03 wow_left wow_right
PCB needed Revisions
- debug documentation should should show all TP pads, and not be the mirror image.
- KS - need to adjust PCB outlines
- height of coin cells is too great. need the original coin cell spec
current sensors
- presently 5V current sensor becomes 3.283V, but ADC reference is 3.0V so of the 75.76A range (0->5V), only 69.23A are viable. Thus range is -37.88A to +31.34A. The scale factor is 65536 / (5/.066 * 3/(5*10/15.23)) = 946.6789
FET
- w/clamp circuit - use thermal vias for R4 - this device is impossible to replace
- will try low temp solder and send to MPD
- populate coin charger as default with 6.3V target voltage (R=1.21meg). If non-rechargeable cells are installed, DNP the connecting resistor. (pg 4/8)
- way to measure coin cell voltage without charger enabled? Connect pin 3 of U10 to something like the SFTYSNS_EN, or MTR_EN signal at TP97 or U20B
- change D13 to diode that actually has 200mV drop @ 1uA. BAS116-F-7 appears to have 427mV @ 0.3uA
SCMC
- pg 7/18 : change cutoff freq to ~15Khz for temp circuit (U22) R102=1k, C73=0.01u
- pg 7/18 : remove R232 - 10k for batt_temp_mon pullup
- pg 7/18 : remove R245 - 220 ohm for mtr_temp_mon pullup
- pg 7/18 : R206, R216 -> 6.66k to scale range 0-5V to 0-3.0V (current sensors)
- pg 7/18 : bridge current sensor use same values phase U,V
- Pg 8/18 : increase size of resisters (by 10x) for supply voltage measurement (R91, R94, R221, R88). Keep cut off freq the same.
- pg 8/18 : populate so measurement of supply voltage is default (R222, R233 installed). its easier to remove components than to add them.
- pg 3/18 : replace 1.25mm header for EC30 enc/hall w/ 12x0.8mm header
- pg 6/18 : replace HALL_C input with SSI_CLK 5V output
- pg 11/18 : (CB) need to determine the accuracy of the RTC. Seems to be drifting.
- pg 18/18 : Remove LSSGA before TP56
- Connect TP56 to LSSGA connector. needs to protect dsPIC, but no other circuity.
- adjust C95 for 15khz cutoff freq
- pg 14/18 : Connect TP252 to LSSGA connector. Needs to protect dsPIC, but no other circuity.
- 3/18 : LSSGA connector signals:
- AGND
- A3V ref
- A 3V supply
- TP56 analog in
- TP252 analog in
- locate IMU header for easier access. possibly rot180 - or move 2mm away from edge.
- KS - lower position for V2.
- CB - in V2 appears to be much more space in the shell, no other changes may be needed.
IMU
- probably want to upgrade dual axis IMU
- battery measurement circuit needs to be re-done.