PCB needed Revisions

  • debug documentation should should show all TP pads, and not be the mirror image.
  • KS - need to adjust PCB outlines
  • height of coin cells is too great. need the original coin cell spec

current sensors

  • presently 5V current sensor becomes 3.283V, but ADC reference is 3.0V so of the 75.76A range (0->5V), only 69.23A are viable. Thus range is -37.88A to +31.34A. The scale factor is 65536 / (5/.066 * 3/(5*10/15.23)) = 946.6789

FET

  • w/clamp circuit - use thermal vias for R4 - this device is impossible to replace
    • will try low temp solder and send to MPD


  • populate coin charger as default with 6.3V target voltage (R=1.21meg). If non-rechargeable cells are installed, DNP the connecting resistor. (pg 4/8)
  • way to measure coin cell voltage without charger enabled? Connect pin 3 of U10 to something like the SFTYSNS_EN, or MTR_EN signal at TP97 or U20B
  • change D13 to diode that actually has 200mV drop @ 1uA. BAS116-F-7 appears to have 427mV @ 0.3uA
    • See : (PDF) - Diodes Inc BAS116-7-F fig 3, pg 2]

SCMC

  • pg 7/18 : change cutoff freq to ~15Khz for temp circuit (U22) R102=1k, C73=0.01u
  • pg 7/18 : remove R232 - 10k for batt_temp_mon pullup
  • pg 7/18 : remove R245 - 220 ohm for mtr_temp_mon pullup
  • pg 7/18 : R206, R216 -> 6.66k to scale range 0-5V to 0-3.0V (current sensors)
  • pg 7/18 : bridge current sensor use same values phase U,V


  • Pg 8/18 : increase size of resisters (by 10x) for supply voltage measurement (R91, R94, R221, R88). Keep cut off freq the same.
  • pg 8/18 : populate so measurement of supply voltage is default (R222, R233 installed). its easier to remove components than to add them.


  • pg 6/18 : replace HALL_C input with SSI_CLK 5V output
  • pg 11/18 : (CB) need to determine the accuracy of the RTC. Seems to be drifting.
  • pg 18/18 : Remove LSSGA before TP56
  • Connect TP56 to LSSGA connector. needs to protect dsPIC, but no other circuity.
    • adjust C95 for 15khz cutoff freq
  • pg 14/18 : Connect TP252 to LSSGA connector. Needs to protect dsPIC, but no other circuity.


  • 3/18 : LSSGA connector signals:
    • AGND
    • A3V ref
    • A 3V supply
    • TP56 analog in
    • TP252 analog in


  • locate IMU header for easier access. possibly rot180 - or move 2mm away from edge.
    • KS - lower position for V2.
    • CB - in V2 appears to be much more space in the shell, no other changes may be needed.

IMU

  • probably want to upgrade dual axis IMU
  • battery measurement circuit needs to be re-done.