  • SC sends commands periodically specifying the (minimum) boost converter output voltage.
    • boost converter is not normally active or switching
  • SC command for emergency shut off, not re-enabled until re-insertion.
  • battery terminals are not normally live. thus impossible to externally short.
  • external power enabled when battery inserted into robot.
    • micro power hall sensor senses a magnet and enables BAF
    • high impedance source that is 'shorted' when connected to robot and enables BAF
    • BAF 'soft starts' robot - avoiding inrush current
  • low voltage (and fuel gauge) shutoff - voltage of each cell is indepentically monitored.
  • impedance tracking of each cell?
  • fuel gauge : micropower current sensor that integrates charge/discharge of battery.
  • electronic fuse : SC sends commands periodically that specify the maximum amount of current and/or power allowed.
  • internal charger and balancer PDF
    • inductive charging.
  • believe a MSP430 micro should be employed. lowest possible power