Difference between revisions of "Upd 2x0 218 controller"

From DIDEAS Wiki
Jump to: navigation, search
m
m (ECOs)
Line 47: Line 47:
  
 
*Replace R86 with a 220 ohm 0402
 
*Replace R86 with a 220 ohm 0402
 +
 +
==lifefix loadwasher measurement=
 +
*replace C73 w/10nF, 0402 NPO
 +
*replace R102 w/2.0K, 1%, 0402

Revision as of 23:38, 30 August 2009

PF Users Navigation:

Edit

SC/MC 2x0-218 PCA

200-218-001

  • 8-6-09 : found on bench. MC doesn't seem to be powered (unable to program)
  • (date unknown - June???) location AK-WB2

200-218-002

  • 8-6-09 : running overnight stress test (+5a, -5a, +5, -5, 3sec off)
  • 8-??-09 : reveived from MPD

200-218-003

  • 4-27-09 : will start testing.
  • needs R233 and R222 shorted (solder ball)

200-218-005

  • location (IW)
  • 4-16-09 : SHORTED R233 and R222 to enable local VBAT MEASUREMENT. DONT CONNECT EXTERNAL BATTERY CABLE
  • location ceb benchtest (MIT), used for code dev

200-218-006

  • 4-25-09 : has problem with MC reset
  • 4-2-09 : start bench test at 3:10am (w/217-006), finished 2pm - works well!


200-218-007

  • 4-6-09 : start bench test at 2am; finished 9:10pm (w/217-007) works well.

200-218-008

  • location (6-26-09) - used for CEB code development at lab

200-218-009

200-218-010

  • 4-2-09 : ran bench test for 1.5 hrs with 217-010

ECOs

Battery voltage measurement

  • solder ball / zero ohm resistor across R222 and R233

EC30-MILE 5V encoder drive

  • Disconnect pin6 of D10 from the signal Hall.C;
  • On J10 (5pin x 1.25mm header) install a 4.7k 0603 resistor between pin 4 (5VDMC) and pin 3 (HALL_C).
  • Replace R86 with a 220 ohm 0402

=lifefix loadwasher measurement

  • replace C73 w/10nF, 0402 NPO
  • replace R102 w/2.0K, 1%, 0402