Difference between revisions of "Upd 2x0 217 power board"

From DIDEAS Wiki
Jump to: navigation, search
m
m
Line 13: Line 13:
 
* if successful, attach to state controller with "testjig" software build and apply 20V limited to 200mA
 
* if successful, attach to state controller with "testjig" software build and apply 20V limited to 200mA
 
* if successful replace missing FET and repeat above power tests.
 
* if successful replace missing FET and repeat above power tests.
 +
 +
== 200-217-002==
 +
*8-6-09 : running overnight stress test (+5a, -5a, +5, -5, 3sec off)
 +
*8-??-09 : received from MPD
 +
  
 
== 200-217-003==
 
== 200-217-003==

Revision as of 03:52, 7 August 2009

PF Users Navigation:

Edit

All BOARDS require Coin cell charger circuit

FET 2x0-217 PCA (power board)

200-217-001

  • 3-28-09 : removed from AK-WB2 w/exploded power FET

todo

  • remove damaged power fet
  • test other power fets (safety fets are on and will complicate this.)
  • if all other tests are positive, apply 10 volts with a 100mA current limit
  • if successful, attach to state controller with "testjig" software build and apply 20V limited to 200mA
  • if successful replace missing FET and repeat above power tests.

200-217-002

  • 8-6-09 : running overnight stress test (+5a, -5a, +5, -5, 3sec off)
  • 8-??-09 : received from MPD


200-217-003

  • 4-27-09 : requires new board testing.



200-217-005

  • 6-26-09 : location CEB lab - used for code dev.
  • 6-26-09 : 5.52 volts on coin cells, dR=0.3mV, dD=427mV iD = 0.3uA. Based on BAS116-7-F datasheet, dD should be <200mV (w/Id=1uA)
  • 6-13-09 : added coin cell recharger circuit. not confident it will charge the batteries.
    • before installed - cell voltages : 2.639, 2.628 total 5.270
    • across R35=2.3mV; across D13=620mV; LDO output=5.955V.
    • later measured R35=34mV, D13=600mV
    • MA621 charge circuit is 3.1V into 1k into cell. Should probably increase LDO output to at least 6.2V possibly 6.3 or 6.4V. Need see what the diode drop looks like. VoutLDO=1.24 * (1+R1/R2)=6.006 as designed.
  • 3-1-09 : Vclamp circuit failed (permanently on) when MPJA power supplied failed.

todo

  • replace PFET and power resistor

200-217-006

  • 4-2-09 : offsets 3001, 2990
  • 4-2-09 : started bench test at 3:20 am, completed 2pm - works well


200-217-007

  • 4-6-09 : started bench test at 2:10 am
  • 4-6-09 : offsets 2914, 2823
  • 4-6-09 : 9:15pm ended test successfully, wiport had disconnected and needs power cylce to reconnect.


200-217-009

  • 4-1-09 : removed from WB1 - possibly damaged
  • 3-28-09 : measured battery voltage at zero and 1.8 volts
  • 3-28-09 : measured terminal to terminal resistance of safety FETs, 38 and 72 ohms
  • 3-1-09 : safety fets are not engaged.

todo

  • replace coin cells (use adhesive to secure batteries to PCA)

200-217-010

  • 4-6-09 : 25amp benchtest for 30 mis with 218-005
  • 4-2-09 : measured coin cells at 2.7++ each.
  • 4-2-09 : bench test for 1.5 hrs with 218-010


ECOs

Coin cell charge voltage

  • replace 1.12Meg resistor w/1.21Meg
  • confirm that LDO voltage is 6.3V +- 0.1V (document in the history file this voltage.)