FET 2x0-217 PCA

200-217-001

  • 3-28-09 : removed from AK-WB2 w/exploded power FET

todo

  • remove damaged power fet
  • test other power fets (safety fets are on and will complicate this.)
  • if all other tests are positive, apply 10 volts with a 100mA current limit
  • if successful, attach to state controller with "testjig" software build and apply 20V limited to 200mA
  • if successful replace missing FET and repeat above power tests.


200-217-005

  • 3-1-09 : Vclamp circuit failed (permanently on) when MPJA power supplied failed.

todo

  • replace PFET and power resistor

200-217-006

  • 4-2-09 : offsets 3001, 2990
  • 4-2-09 : started bench test at 3:20 am, completed 2pm - works well

200-217-009

  • 4-1-09 : removed from WB1 - possibly damaged
  • 3-28-09 : measured battery voltage at zero and 1.8 volts
  • 3-28-09 : measured terminal to terminal resistance of safety FETs, 38 and 72 ohms
  • 3-1-09 : safety fets are not engaged.

todo

  • replace coin cells (use adhesive to secure batteries to PCA)

200-217-010

  • 4-2-09 : measured coin cells at 2.7++ each.
  • 4-2-09 : bench test for 1.5 hrs with 218-010