Difference between revisions of "Upd 2x0 217 power board"

From DIDEAS Wiki
Jump to: navigation, search
m
m
Line 17: Line 17:
 
== 200-217-005==
 
== 200-217-005==
 
*3-1-09 : Vclamp circuit failed (permanently on) when MPJA power supplied failed.
 
*3-1-09 : Vclamp circuit failed (permanently on) when MPJA power supplied failed.
 +
 
===todo===
 
===todo===
* replaced PFET and power resistor
+
* replace PFET and power resistor
 +
 
 +
 
 +
== 200-217-005==
 +
*3-28-09 : measured battery voltage at zero and 1.8 volts
 +
*3-28-09 : measure pole to pole of safety FETs, 38 and 72 ohms. -> battery
 +
*3-1-09 : safety fets are not engaged. 
 +
 
 +
===todo===
 +
* replace coin cells (use adhesive to secure batteries to PCA)

Revision as of 22:25, 28 March 2009


FET 2x0-217 PCA

200-217-001

  • 3-28-09 : removed from AK-WB2 w/exploded power FET

todo

  • remove damaged power fet
  • test other power fets (safety fets are on and will complicate this.)
  • if all other tests are positive, apply 10 volts with a 100mA current limit
  • if successful, attach to state controller with "testjig" software build and apply 20V limited to 200mA
  • if successful replace missing FET and repeat above power tests.


200-217-005

  • 3-1-09 : Vclamp circuit failed (permanently on) when MPJA power supplied failed.

todo

  • replace PFET and power resistor


200-217-005

  • 3-28-09 : measured battery voltage at zero and 1.8 volts
  • 3-28-09 : measure pole to pole of safety FETs, 38 and 72 ohms. -> battery
  • 3-1-09 : safety fets are not engaged.

todo

  • replace coin cells (use adhesive to secure batteries to PCA)