Difference between revisions of "Upd 219 imu"

From DIDEAS Wiki
Jump to: navigation, search
m
m
Line 1: Line 1:
*[[PF Top Nav]]; [[Upd_pcb | PCB]]; [[Aiw_hardware | Hardware]]; [[AIW_assembly | Assembly]]  [[PFMENU DOCS | PFCmdMenu]]  [[iochan]]
+
{{pf_top_nav}}
*PCA : [[Upd_2x0_218_controller | SC/MC 218]] [[Upd_2x0_217_power_board| FET 217]] [[Upd_219_imu | IMU219]] [[Wip4a-spi | Swiffy]] [[Rev200_mods]] 
 
*PFCMD : [[PFMENU_DOCS | SC]]; [[PFMENU_DOCS_MC | MC]]; [[PFCMD_PY]];  [[Pf_calb_table_py]]; [[Virtual spring test]]; [[PF1_Code_History]]; [[PF EEPROM]]
 
 
 
  
  

Revision as of 02:28, 7 August 2009

PF Users Navigation:

Edit



PFMENU DOCS Aiw_hardware iochan AIW_assembly

ECOs

ADC OVERVOLTAGE ECO (COMPLETED ON #1-#3)

The circuit to measure the supply voltage causes an over voltage condition on the ADCs - corrupting all measurements.

  • replace R43 w/1.0meg resistor

ADXR610 fullscale / bandwidth ECO

  • Remove R45 (267k) - changes max rate of ADXRS610
  • Change C56 to 6.31nF (no standard value of CAPS, might use 5.6nF+400pF? or 6.7nF....)
  • this pair of modifications results in the ADXRS610 BW = 140hz.

IMU

  • w/Cout=33nF, and R45=267, Bw=45 hz
  • All signals have 1.6Khz BW going into dSPIC
  • IDG300 internal RC filter of 140 Hz - internal drive freq >= 10khz. should choose sample rate to move peak into high end of digital sample band.

1

  • 7-13-09 : changed R43 to 1.0meg
  • 7-3-09 : location IW. reprogram with firmware that supports command 2020
  • 6-26-09 : location CEB lab
  • 6-23-09 : seems to be working
  • 1-24-09 : boots and can reprogram - this will be the IMU development device.
  • 1-24-09 : removed broken jumper wires from GND to R28. Shorted Q4 gate to ground.
  • 1-24-09 : is missing pushbutton switch and is missing PB pad. Remain 3 pads don't seem to be enough to switch the system on.


2

  • 7-13-09 : changed R43 to 1.0meg
  • 7-10-09 : switcher replaced.
  • 7-2-09 : IMU#2 - doesn't power with either of 2 cables. probably due to review polarity cable - probably needs new switcher.
  • 6-23-09 : seems to be working with 'blue' cable w/red and black marks on connector
  • 1-24-09 : was able to erase and reprogram.
  • 1-24-09 : system is getting 3.3V w/push button - however, unable to program over protected segments

3

  • 7-13-09 : changed R43 to 1.0meg
  • 6-23-09 : seems to be working. appears to have been relabeled with #1 (despite the #3 appearing on two ICs.) removed label
  • 1-24-09 : switching regulator gets voltage w/PB, however, 3.3V is unchanged.

todo

  • replace switcher U7

IMU cables

  • IMU cables with red wire are all subject to intermittent connections due to large wire size. use a small screw driver or xacto to press wires back into IDC slots.

pinout (new SC Rev200 -> IMU cable

  • 12pin -> 10pin
  • 1 -> 10
  • 2 -> NC
  • 3 -> 7
  • 4 -> 6
  • 5 -> 5
  • 6 -> 4
  • 7 -> 2
  • 8 -> 9
  • 9 -> 8
  • 10 -> NC
  • 11 -> 1
  • 12 -> NC


pinout (old SC Rev100->IMU) cable

  • 12pin -> 10pin
  • 1 -> 1 (VBAT)
  • 2 -> NC
  • 3 -> 4 (SS)
  • 4 -> 5 (SLK)
  • 5 -> 6 (MOSI)
  • 6 -> 7 (MISO)
  • 7 -> 9 (SRVC)
  • 8 -> 2 (DEBUG)
  • 9 -> 3 (SCPWREN)
  • 10 -> NC
  • 11 -> 10 (GND)
  • 12 -> NC