Difference between revisions of "Upd 219 imu"

From DIDEAS Wiki
Jump to: navigation, search
m
m (2)
Line 35: Line 35:
  
 
==2==
 
==2==
*7-13-09 : change R43 to 1.0meg
+
*7-13-09 : changed R43 to 1.0meg
 +
*7-10-09 : switcher replaced.
 
*7-2-09 : IMU#2 - doesn't power with either of 2 cables.  probably due to review polarity cable - probably needs new switcher.
 
*7-2-09 : IMU#2 - doesn't power with either of 2 cables.  probably due to review polarity cable - probably needs new switcher.
 
*6-23-09 : seems to be working with 'blue' cable w/red and black marks on connector
 
*6-23-09 : seems to be working with 'blue' cable w/red and black marks on connector
 
*1-24-09 : was able to erase and reprogram.
 
*1-24-09 : was able to erase and reprogram.
 
*1-24-09 : system is getting 3.3V w/push button - however, unable to program over protected segments
 
*1-24-09 : system is getting 3.3V w/push button - however, unable to program over protected segments
===todo===
 
*diagnose problem, probably replace Vin switcher
 
  
 
==3==
 
==3==

Revision as of 01:16, 14 July 2009



PFMENU DOCS Aiw_hardware iochan AIW_assembly

ECOs

ADC OVERVOLTAGE ECO (COMPLETED ON #1-#3)

The circuit to measure the supply voltage causes an over voltage condition on the ADCs - corrupting all measurements.

  • replace R43 w/1.0meg resistor

ADXR610 fullscale / bandwidth ECO

  • Remove R45 (267k) - changes max rate of ADXRS610
  • Change C56 to 6.31nF (no standard value of CAPS, might use 5.6nF+400pF? or 6.7nF....)
  • this pair of modifications results in the ADXRS610 BW = 140hz.

IMU

  • w/Cout=33nF, and R45=267, Bw=45 hz
  • All signals have 1.6Khz BW going into dSPIC
  • IDG300 internal RC filter of 140 Hz - internal drive freq >= 10khz. should choose sample rate to move peak into high end of digital sample band.

1

  • 7-13-09 : change R43 to 1.0meg
  • 7-3-09 : location IW. reprogram with firmware that supports command 2020
  • 6-26-09 : location CEB lab
  • 6-23-09 : seems to be working
  • 1-24-09 : boots and can reprogram - this will be the IMU development device.
  • 1-24-09 : removed broken jumper wires from GND to R28. Shorted Q4 gate to ground.
  • 1-24-09 : is missing pushbutton switch and is missing PB pad. Remain 3 pads don't seem to be enough to switch the system on.


2

  • 7-13-09 : changed R43 to 1.0meg
  • 7-10-09 : switcher replaced.
  • 7-2-09 : IMU#2 - doesn't power with either of 2 cables. probably due to review polarity cable - probably needs new switcher.
  • 6-23-09 : seems to be working with 'blue' cable w/red and black marks on connector
  • 1-24-09 : was able to erase and reprogram.
  • 1-24-09 : system is getting 3.3V w/push button - however, unable to program over protected segments

3

  • 7-13-09 : change R43 to 1.0meg
  • 6-23-09 : seems to be working. appears to have been relabeled with #1 (despite the #3 appearing on two ICs.) removed label
  • 1-24-09 : switching regulator gets voltage w/PB, however, 3.3V is unchanged.

todo

  • replace switcher U7

IMU cables

  • IMU cables with red wire are all subject to intermittent connections due to large wire size. use a small screw driver or xacto to press wires back into IDC slots.

pinout (new SC Rev200 -> IMU cable

  • 12pin -> 10pin
  • 1 -> 10
  • 2 -> NC
  • 3 -> 7
  • 4 -> 6
  • 5 -> 5
  • 6 -> 4
  • 7 -> 2
  • 8 -> 9
  • 9 -> 8
  • 10 -> NC
  • 11 -> 1
  • 12 -> NC


pinout (old SC Rev100->IMU) cable

  • 12pin -> 10pin
  • 1 -> 1 (VBAT)
  • 2 -> NC
  • 3 -> 4 (SS)
  • 4 -> 5 (SLK)
  • 5 -> 6 (MOSI)
  • 6 -> 7 (MISO)
  • 7 -> 9 (SRVC)
  • 8 -> 2 (DEBUG)
  • 9 -> 3 (SCPWREN)
  • 10 -> NC
  • 11 -> 10 (GND)