==110-006==
 
==110-006==
 +
*12-04-08 : added [[force power on ECO]] and verified that power board lights
 
*12-03-08 : U39 has been replaced with LT3470AEDDB#PBF  
 
*12-03-08 : U39 has been replaced with LT3470AEDDB#PBF  
 
*11-26-08 : NEEDS U39 replaced
 
*11-26-08 : NEEDS U39 replaced
Line 33: Line 34:
 
===ECOs===
 
===ECOs===
 
* has [[battery voltage ECO]]
 
* has [[battery voltage ECO]]
 +
* has [[force power on ECO]]
  
 
==110-007 ==
 
==110-007 ==

Revision as of 05:13, 4 December 2008

PFMENU DOCS Aiw_hardware iochan

Gmail Powerfoot tracker

  • Operational:
  • SC : 205, 09, 08
  • PB : 004

State / Motor Controller

100-8A (BF2)

  • Motor control NOT operational (State operational)

TODO


110-006

  • 12-04-08 : added force power on ECO and verified that power board lights
  • 12-03-08 : U39 has been replaced with LT3470AEDDB#PBF
  • 11-26-08 : NEEDS U39 replaced
  • 11-25-08: Not operational
  • 11-19-08 : traced MC power. Found that 3.3V supply only goes 1V - applied 3.3V from prg adpt and MC booted. Forced R155 high and 5V MC supply worked.
  • 11-19-08 : appears that MC switcher is bad. Apply 3.3V to ISP, SC boots, but MC does not.
  • 11-8-08 : requires external device to hold it on...
  • 10-6-08 : installed in UP#3

TODO

Needs to be tested

ECOs

110-007

  • 11-30-08 : 1st current sensor has large offset
  • 11-30-08 : appears that solder on a 1210 cap was making case contact. This was corrected, and tape is being put on the case surface.
  • 11-28-08 : installed into ankle#2, appears to have trouble turning on - staying on. Appears to be caused by rework and raised components shorting to case.
  • 11-28-08 : Ran 36 hrs test with Upd_pcb#110-005
  • 11-26-08 : operational
  • 11-26-08 : R102 missing this is a pull up on the real time clock
  • 11-26-08 : added R141 to GND ECO (force power on)
  • 11-25-08 : Applied power, not operational
  • 11-19-08 : Applied power, seems to run okay.
  • 11-19-08 : Needs 3.3V to poweron status : component gets hot.
  • 10-8-08 : received from UPD - tested - seems to be DOA
  • 10-7-08 : received by UPD
  • 10-6-08 : died in ankle while using the battery and under high current load - traced to 3.3V motor controller supply not working. Was used with power board that has TVS installed on caps, and external TVS were also used. Died
  • 10-5-08 : installed in UP#3, made battery measurement ECO

TODO

  • install R102
  • verify that current filter caps are correct

ECOs

110-008

  • 11-26-08 : appears that the motor controller dsPIC is unpowered.
  • 11-19-08 : Rob added GND connection to keep board powered on (either at TP93 or otherside R141)
  • 11-19-08 : Applied 3.3V to ISP header and SC booted.
  • 11-19-08 : IMU #2 connected, push switch and won't power up
  • 10-5-08 : need to evaluate
  • 10-4-08 : Removed from UP#3, as randomly powers on at ~10hz due to noise? possibly damaged due to the pushbutton that WAS attached.
  • 10-1-08 : Modified for auto-off : requires external signal for power on, has MC battery voltage ECO

TODO

  • Diagnose failure

ECOs



110-009

(BF1)

  • 11-29-08 : operational - tested with PB 100-002
  • 11-26-08 : operational, but missing CAP in middle row (C142?)
  • 11-20-08 : Needs the 24 pin flex connect to be replaced. (replaced 11-25-08)
  • 11-19-08 : Needs battery measurement modification.
  • 11-8-08 : has jumper wire to turn self on, but wouldn't boot until IMU attached. After first power, remove IMU and works fine.

TODO

110-205

  • 11-30-08 : verified with Upd_test_pattern_112608a for 3 hrs, using PB 110-004
  • 11-30-08 : CEB added jumper to keep power on.
  • 11-29-08 : seems operational
  • 11-26-08 : needs 3.3V to be applied to get started.
  • 11-25-08 : flex connector replaced

TODO

ECOs

Power Board

100-002

  • 11-29-08 : Simple verification with SC 110-205, seems operational. 5 mins of Upd_test_pattern_112608a
  • 11-27-08 : Failed during high RPM test. Application of 30V suggests that all the installed TVS devices have failed. PB Led is off, no 12V supply. Bypassed Q2 and 12V supply started. Removed power, and 12V supply still worked.


Possibly used to be 110-ENG2

TODO

ECOs

110-004

  • 11-30-08 : SC 110-205 ran Upd_test_pattern_112608a for 3 hrs
  • 11-29-08 : simple verification with SC 110-205
  • 11-26-08 : benched tested for 3 days.
  • 11-26-08 : has 2.0 ohm gate drive
  • 11-26-08 : has 225W TVS on bypass caps.

TODO

ECOs

110-005

  • 10-8-08 : installed in upright2; during power platarflexion tests heard noises of instability from motor. reduce motor filter (Q & D) to PWM max of 20k (from 30k). During one test, the motor system seized (making noise) and 17amps was coming from the battery. Afterwards, attempts to energy mode 2/3 caused 1.1amp current draw from power supply


TODO

ECOs

110-007

  • 11-29-08 : BROKEN - spins fine in positive direction, but negative is very broken
  • 11-27-08 : appears to have failed turning overnight test. Originally - VBAT_PROT didn't make it to the 12V switcher.
  • 11-26-08 : operational

TODO

ECOs

110-008

  • 11-26-08 : is operational, but seems like it might be warm. I=180mA in mode 3, 0 torque. Added schottky and still gets warm (Hot). Upto 280mA depending on motor angle.

TODO

  • diagnose large power draw


ECOs

IMU

Blue radio

Wifi radio