=reference=
 
=reference=
*[https://bmech.media.mit.edu:8443/svn/ric_powerfoot/  SVN server]  user=ric, pass=ric#### where # is Levi's office #
+
*[https://bmech.media.mit.edu:8443/svn/ric_powerfoot/  SVN server]   
 +
** for RIC : user=ric, pass=ric#### where # is Levi's office #
 +
** for biomech : user=biomech, pass=biomech### where # is the office number for the group
  
 
=tools setup=
 
=tools setup=

Revision as of 19:43, 6 April 2010

Make PFF adjustment smaller.

Wiki for RIC robot project

getting started

All software can be open via short cuts in a folder on the desktop.

program for tuning and data collection

  • open cmd prompt to "support_scripts" and run "capture <filename>". capture.bat may need to be edited should the COM port # change.
  • open matlab, change to c:\mit_ankle\support_scripts" and run "plot_float". Use port# 9999
  • make sure the CPU is not loaded -else the serial port will drop data. (char 'S' output) in DOS window
  • unlock robot with "F4"
  • to start "PWM" hit ALT-F1
  • to stop "PWM" hit ALT-F2

reference

  • SVN server
    • for RIC : user=ric, pass=ric#### where # is Levi's office #
    • for biomech : user=biomech, pass=biomech### where # is the office number for the group

tools setup

mplab IDE config

To load a PF project, the default settings of the MPLAB IDE need to be changed:

  1. open "MPLAB IDE"
  2. Under Configure -> Settings select the "projects" tab
  3. Uncheck the "use one-to-one project-workspace model"

Some other suggested changes:

  • From the "other" tab, select "automatically reload"
  • From the "workspace" tab, select "no", "reload last workspace", and "always show full path"

Some programmer settings could also be changed:

  • Select Programmer -> settings and then "Program after successful build"

After this works, try to open and compile a workspace/project.

  1. From MPLAB IDE, select "File, Open Workspace"
  2. Navigate to "trunk/StateController" and open "sc_workspace_mit.mcw" (or similar)
  3. Ignore complaint about files having been relocated.
  4. after it opens, press "Ctrl F10" to do a "make clean" followed by "make all"

python config

A file that describes the directory structure of the project needs to be placed in c:\

  • Edit the file "support_scripts\python_paths.py", so that variables point the root of your project tree.
  • The root of your project tree the directory that contains the directories "support_scripts" and "pf_python"
  • the string "c:\ceb\0svn" is replaced with your root.
  • Afterward, copy it to c:\

The python interpreter needs to be added to the system path:

  • Ctrl click "My Computer" and then select "Properties"
  • From the new object, select the "Advanced" tab
  • Select "Environment Variables"
  • To the "PATH" variable, append "c:\python25;"
    • The path variable may exist under "user variable" or "system variables"
  • Verify that python is in the system path by starting a DOS prompt and running python

make a wifi connection

From the support scripts folder run :

  • FOR S3 : wifi_fast.py -i 216 -F -f xx -V dataport0
  • FOR S5 : wifi_fast.py -i 218 -F -f xx -V hall2
  • for today : http://18.85.54.30