*~35 volts on 10,000uF cap applied to circuit via circuit breaker.
 
*~35 volts on 10,000uF cap applied to circuit via circuit breaker.
 +
**blue trace is V+ and V- on the array
 +
** other traces are voltage across the 0.47 resistors.
 
[http://dhcp-17-197.media.mit.edu/ankle/scope_capture/dclamp1-pulse-strong-and-week--wrt-ave.png]
 
[http://dhcp-17-197.media.mit.edu/ankle/scope_capture/dclamp1-pulse-strong-and-week--wrt-ave.png]

Revision as of 20:23, 12 April 2009

dclamp1

Serial #1:

(only passive portion of circuit assembled.)

w/Itest = 89mA

(mV) voltage across (.47ohm) is:

2.5   5.7   1.4    2.3   2.3
1.3   3.0   2.0   14.8   1.8

 R6   R7    R8     R9    R10
 R5   R4    R3     R2    R1

Circuit voltage with test current:

  • 1mA 27.8V
  • 10mA 28.04V
  • 100mA 28.6V

scope captures

  • ~35 volts on 10,000uF cap applied to circuit via circuit breaker.
    • blue trace is V+ and V- on the array
    • other traces are voltage across the 0.47 resistors.

[1]