Robert Todo

  • Verify operation of RE40 encoder new motor test stand. Appears to not be working
  • Rewire 8-cell A123 battery pack to 7cell.
  • programming cable in PCB repair box is bad.
  • Build Vclamp8 with NEW PFET and 35w resistor
  • Ship 1 Vclamp8 to UPD


CEB todo

  • current measurement PCB (with Y voltage measure)
  • encoder breakout boards
  • SG breakout boards


State / Motor Controller

110-006

  • 11-26-08 : NEEDS U39 replaced
  • 11-25-08: Not operational
  • 11-19-08 : traced MC power. Found that 3.3V supply only goes 1V - applied 3.3V from prg adpt and MC booted. Forced R155 high and 5V MC supply worked.
  • 11-19-08 : appears that MC switcher is bad. Apply 3.3V to ISP, SC boots, but MC does not.
  • 11-8-08 : requires external device to hold it on...
  • 10-6-08 : installed in UP#3

TODO

  • replace U39

ECOs


110-007

  • 11-26-08 : operational
  • 11-26-08 : R102 missing this is a pull up on the real time clock
  • 11-26-08 : added R141 to GND ECO (force power on)
  • 11-25-08 : Applied power, not operational
  • 11-19-08 : Applied power, seems to run okay.
  • 11-19-08 : Needs 3.3V to poweron status : component gets hot.
  • 10-8-08 : received from UPD - tested - seems to be DOA
  • 10-7-08 : received by UPD
  • 10-6-08 : died in ankle while using the battery and under high current load - traced to 3.3V motor controller supply not working. Was used with power board that has TVS installed on caps, and external TVS were also used. Died
  • 10-5-08 : installed in UP#3, made battery measurement ECO

TODO

  • install R102

ECOs



110-008

  • 11-26-08 : appears that the motor controller dsPIC is unpowered.
  • 11-19-08 : Rob added GND connection to keep board powered on (either at TP93 or otherside R141)
  • 11-19-08 : Applied 3.3V to ISP header and SC booted.
  • 11-19-08 : IMU #2 connected, push switch and won't power up
  • 10-5-08 : need to evaluate
  • 10-4-08 : Removed from UP#3, as randomly powers on at ~10hz due to noise? possibly damaged due to the pushbutton that WAS attached.
  • 10-1-08 : Modified for auto-off : requires external signal for power on, has MC battery voltage ECO

TODO

  • Diagnose failure

ECOs



110-009 (BF1)

  • 11-26-08 : operational
  • 11-20-08 : Needs the 24 pin flex connect to be replaced. (replaced 11-25-08)
  • 11-19-08 : Needs battery measurement modification.
  • 11-8-08 : has jumper wire to turn self on, but wouldn't boot until IMU attached. After first power, remove IMU and works fine.

TODO

Power Board

110-004

  • 11-26-08 : benched tested for 3 days.
  • 11-26-08 : has 2.0 ohm gate drive
  • 11-26-08 : has 225W TVS on bypass caps.

TODO



110-205

  • 11-26-08 : no lights of any kind, use IMU to attempt power on
  • 11-25-08 : flex connector replaced

TODO

  • diagnose failure

ECOs




IMU

Blue radio

Wifi radio