Difference between revisions of "Upd pcb"

From DIDEAS Wiki
Jump to: navigation, search
m (Robert Todo)
m
Line 5: Line 5:
 
* Build Vclamp8 with NEW PFET and 35w resistor
 
* Build Vclamp8 with NEW PFET and 35w resistor
 
* Ship 1 Vclamp8 to UPD
 
* Ship 1 Vclamp8 to UPD
 +
 +
 +
 +
= CEB todo=
 +
* current measurement PCB (with Y voltage measure)
 +
* encoder breakout boards
 +
* SG breakout boards
 +
  
 
=State / Motor Controller=
 
=State / Motor Controller=
Line 42: Line 50:
 
* has [[battery voltage ECO]]
 
* has [[battery voltage ECO]]
 
* has [[force power on ECO]]
 
* has [[force power on ECO]]
 +
 +
 +
 +
 +
==110-008==
 +
 +
 +
 +
 +
 +
 +
  
 
==110-009  (BF1) ==
 
==110-009  (BF1) ==

Revision as of 22:58, 26 November 2008

Robert Todo

  • Verify operation of RE40 encoder new motor test stand. Appears to not be working
  • Rewire 8-cell A123 battery pack to 7cell.
  • programming cable in PCB repair box is bad.
  • Build Vclamp8 with NEW PFET and 35w resistor
  • Ship 1 Vclamp8 to UPD


CEB todo

  • current measurement PCB (with Y voltage measure)
  • encoder breakout boards
  • SG breakout boards


State / Motor Controller

110-006

  • 11-26-08 : NEEDS U39 replaced
  • 11-25-08: Not operational
  • 11-19-08 : traced MC power. Found that 3.3V supply only goes 1V - applied 3.3V from prg adpt and MC booted. Forced R155 high and 5V MC supply worked.
  • 11-19-08 : appears that MC switcher is bad. Apply 3.3V to ISP, SC boots, but MC does not.
  • 11-8-08 : requires external device to hold it on...
  • 10-6-08 : installed in UP#3

TODO

  • replace U39

ECOs


110-007

  • 11-26-08 : operational
  • 11-26-08 : R102 missing this is a pull up on the real time clock
  • 11-26-08 : added R141 to GND ECO (force power on)
  • 11-25-08 : Applied power, not operational
  • 11-19-08 : Applied power, seems to run okay.
  • 11-19-08 : Needs 3.3V to poweron status : component gets hot.
  • 10-8-08 : received from UPD - tested - seems to be DOA
  • 10-7-08 : received by UPD
  • 10-6-08 : died in ankle while using the battery and under high current load - traced to 3.3V motor controller supply not working. Was used with power board that has TVS installed on caps, and external TVS were also used. Died
  • 10-5-08 : installed in UP#3, made battery measurement ECO

TODO

  • install R102

ECOs



110-008

110-009 (BF1)

  • 11-26-08 : operational
  • 11-20-08 : Needs the 24 pin flex connect to be replaced. (replaced 11-25-08)
  • 11-19-08 : Needs battery measurement modification.
  • 11-8-08 : has jumper wire to turn self on, but wouldn't boot until IMU attached. After first power, remove IMU and works fine.

TODO

Power Board

110-004

  • 11-26-08 : benched tested for 3 days.
  • 11-26-08 : has 2.0 ohm gate drive
  • 11-26-08 : has 225W TVS on bypass caps.

TODO






IMU

Blue radio

Wifi radio