Difference between revisions of "QAKAMP"

From DIDEAS Wiki
Jump to: navigation, search
m
 
m
 
(8 intermediate revisions by 2 users not shown)
Line 1: Line 1:
 +
[[Biomechatronics_Documentation | Back to BM]]
 +
[[Ankle-0406 | Ankle Tech notes]]
 +
[[GIMUAMP | Greddy IMU amplifer (GIMUAMP)]]
 +
[[AKBRK | Ankle MM32 breakout (AKBRK)]]
  
  
 
QAKAMP contains four bridge amplifiers with 2+ pole LP filters and differential output drivers, a high current precision voltage reference, power supply conditioning.  The front end uses instrumentation amplifier with 80dB CMR extending to 100KHz.
 
QAKAMP contains four bridge amplifiers with 2+ pole LP filters and differential output drivers, a high current precision voltage reference, power supply conditioning.  The front end uses instrumentation amplifier with 80dB CMR extending to 100KHz.
 +
 +
 +
=Rev A=
 +
*LM358 and OP27 opamp power wired backwards - corrected in Rev B schematic
 +
*V- LED wired backwards in SCH, corrected in Rev B sch
 +
*L.COM at REF- is open circuit - connected to COM
 +
 +
==SN1 : assembly notes==
 +
*Vref built with TL1431, Rb=2.49, Ra=4.7k -> Vref = 7.2v - regulation @ +-10V
 +
*changed Ra to 2.49k, Vref = 4.99V, regulation @ +6, -7V
 +
*RR1,RR4 are 4.7 and 10k.  Wonder if smaller values might start regulation sooner.

Latest revision as of 22:40, 1 June 2006

Back to BM Ankle Tech notes Greddy IMU amplifer (GIMUAMP) Ankle MM32 breakout (AKBRK)


QAKAMP contains four bridge amplifiers with 2+ pole LP filters and differential output drivers, a high current precision voltage reference, power supply conditioning. The front end uses instrumentation amplifier with 80dB CMR extending to 100KHz.


Rev A

  • LM358 and OP27 opamp power wired backwards - corrected in Rev B schematic
  • V- LED wired backwards in SCH, corrected in Rev B sch
  • L.COM at REF- is open circuit - connected to COM

SN1 : assembly notes

  • Vref built with TL1431, Rb=2.49, Ra=4.7k -> Vref = 7.2v - regulation @ +-10V
  • changed Ra to 2.49k, Vref = 4.99V, regulation @ +6, -7V
  • RR1,RR4 are 4.7 and 10k. Wonder if smaller values might start regulation sooner.